Mga produkto

  • GDUP-3000 Pure Sine Wave AC Power Supply

    GDUP-3000 Pure Sine Wave AC Power Supply

    Ang GDUP-3000 ay isang versatile portable pure sine wave on-site AC test power supply.Kilala rin bilang on-site na AC at DC test power supply, AC at DC emergency power supply, field test power supply, mobile test power supply.

  • GDUP-1000 Versatile Portable Pure Sine Wave On-site AC Test Power Supply

    GDUP-1000 Versatile Portable Pure Sine Wave On-site AC Test Power Supply

    Ang GDUP-1000 ay isang versatile portable pure sine wave on-site AC test power supply.Kilala rin bilang on-site na AC at DC test power supply, AC at DC emergency power supply, field test power supply, mobile test power supply.

  • GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer

    GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer

    Ang GDC-9560B Gas Chromatograph Analyzer ay upang pag-aralan ang gas content ng insulation oil sa pamamagitan ng gas chromatographic method.Ito ay epektibong hatulan kung ang tumatakbong kagamitan ay may potensyal na pagkakamali tulad ng sobrang init, discharge o hindi, upang matiyak ang kaligtasan ng power grid.

  • GDOH-II Insulating Oil Gas Content Tester

    GDOH-II Insulating Oil Gas Content Tester

    Ang GDOH-II Insulating Oil Gas Content Tester ay isang bagong henerasyong tester na gumagamit ng imported na high accuracy sensor at ang pinakabagong teknolohiya ng sensor.Ito ay batay sa DL423-91 na pamantayan ng industriya ng kuryente at mga kaugnay na pambansang pamantayan.

  • GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)

    GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)

    Ang teknolohiyang Coulometric Karl Fischer ay inilapat upang sukatin ang tumpak na pagsubaybay sa kahalumigmigan na nilalaman ng sinusukat na sample. Ang teknolohiya ay malawakang ginagamit para sa katumpakan at murang gastos sa pagsubok. Ang Modelong GDW-102 ay sumusukat nang tumpak sa pagsubaybay sa kahalumigmigan sa mga sample ng likido, solid at gas ayon sa teknolohiya.

  • GDBS-305 Awtomatikong Flash Point Closed Cup Tester

    GDBS-305 Awtomatikong Flash Point Closed Cup Tester

    Ang GDBS-305 automatic closed cup flash point tester ay ang device na sumusubok sa closed cup flash point para sa mga produktong petrolyo.Gumagamit ito ng disenyo ng module kung saan maaaring kontrolin ng isang host ang ilang testing furnace, upang subukan ang iba't ibang sample nang sabay o hiwalay.

  • GDZD-601 Awtomatikong Multi-Function Insulation Oil Shaker

    GDZD-601 Awtomatikong Multi-Function Insulation Oil Shaker

    Ang Multi-Function Shaker ay ginagamit sa laboratoryo upang subukan ang init, pag-iling, pag-degas ng iba't ibang uri ng likido sa ilalim ng pare-parehong temperatura at isang nakapirming oras.Ito ay kinokontrol ng micro-computer upang mapagtanto ang pakikipag-ugnayan ng tao-machine.

  • AC High Voltage Test Sets para sa GIS

    AC High Voltage Test Sets para sa GIS

    Ang AC Resonant Test System para sa Substation Electrical Equipment, ay pangunahing binubuo ng variable frequency power supply, Excitation Transformers, Reactors, Capacitive dividers, na idinisenyo para sa AC withstand voltage test ng substation electric equipment sa 500kV o mas mababa.

     

     

  • PD Free Variable Frequency Test System

    PD Free Variable Frequency Test System

    Ang GDYT-350kVA/70kV PD free Resonant Test System ay binubuo ng PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, at capacitive voltage divider.

     

     

     

     

     

     

  • Hipot Test Set na May Awtomatikong Kontrol

    Hipot Test Set na May Awtomatikong Kontrol

    Ang AC hi-pot testing ay ang mabisa at direktang paraan upang subukan ang lakas ng pagkakabukod para sa mga de-koryenteng kagamitan, apparatus o makina.Sinusuri nito ang mga mapanganib na depekto na nagsisiguro sa mga de-koryenteng kagamitan na patuloy na gumagana.

  • Battery Impedance Tester GDBT-8612

    Battery Impedance Tester GDBT-8612

    Bilang isang pangunahing bahagi ng sistema ng kuryente, ang mga baterya ay dapat na masuri at mapanatili taun-taon, quarterly o kahit buwan-buwan at ang kanilang data ng pagsubok ay kailangang suriin nang regular.

  • GDZRS-20A Three Phase DC Winding Resistance Tester

    GDZRS-20A Three Phase DC Winding Resistance Tester

    Ang DC resistance quick tester na ito (mula dito ay tinutukoy bilang ang DC winding resistance tester) ay ang pinakabagong henerasyong produkto para sa pagsukat ng DC resistance ng mga transformer.Ito ay na-optimize para sa pagsukat ng DC resistance ng tatlong-phase windings ng malalaking-capacity na mga transformer.Ang DC resistance ng tatlong-phase windings ng transpormer ay maaaring masuri nang sabay-sabay.Para sa on-load na boltahe na nagre-regulate ng transpormer, hindi kinakailangang direktang i-discharge ang tap changer, at ang oras ng pagsukat ay 1/3 ng tradisyonal na single-phase na pagsukat, na maaaring lubos na paikliin ang oras ng pagtatrabaho at labor intensity.Ang direct resistance meter ay gumagamit ng malaking-screen na liquid crystal display, lahat ng Chinese graphical interface, malinaw at madaling maunawaan, at ang operasyon ay napakasimple.At nilagyan ng panel printer at malaking kapasidad na non-volatile memory, madali mong maiimbak at mai-print ang mga resulta ng pagsukat.Ang data ng pagsubok ay matatag, mabilis at nauulit, at ito ang pinakamahusay na pagpipilian para sa pagsukat ng DC resistance ng mga transformer sa site.

Ipadala ang iyong mensahe sa amin:

Isulat ang iyong mensahe dito at ipadala ito sa amin